SUMMARY:2-day Training Seminar on EU Code of Conduct for Data Center E
 nergy Efficiency
DESCRIPTION:In response to the rising challenges facing data centre op
 erators, owners, systems designers, equipment manufacturers and custom
 ers, the European Commission have introduced the Code of Conduct for E
 nergy Efficiency in Data Centres. The Code aims to raise awareness of 
 the issues and opportunities and to recommend best practice solutions.
  We introduces the Code, the benefits it brings, the levels of commitm
 ent required, the technical background to the best practices, data col
 lection and reporting together with real examples.\n\nThis 2-day train
 ing seminar enables individuals working in data centres to improve cos
 t and energy efficiency. The ongoing development of the Code encompass
 es topics associated with new data centre planning, design and develop
 ment, and the tuning and operation of existing facilities.\n\nAll sect
 ions are conducted by Chartered Engineers (CEng) and help you to appro
 ach best practices in designing and operating energy efficient data ce
 nters by our further technical programs.\n Day 1 Content\n \n- Define
 , identify and list data center best practice sections\n- Power distri
 bution in data center - the power tree\n- Optimizing the data centre r
 equirements\n- Area of responsibilities (physical building, mechanical
  & electrical plant, data floor, racks, etc.)\n- Efficient cooling 1 (
 hot / cold aisle containment, raised floor, ceiling height, airflow co
 ntrol, etc.)\n- Efficient cooling 2 (CRAC settings, arrangement of cab
 le trays, cabinets and cooling plants, etc.)\n- Efficient cooling 3 (a
 ir free cooling, water free cooling, mechanism of absorption chiller, 
 etc.)\n- Interactions and interdependencies of various systems\n- Stan
 dby UPS\n- Standby ferro UPS\n- Line interactive UPS\n- Double convers
 ion on-line UPS\n- Delta conversion on-line UPS\n- Temperature and hum
 idity control - Factors affecting data center energy consumption\n \n
 Day 2 Content\n \n- Resilience level and provisioning\n- Data center 
 efficiency and Uptimes Tier levels requirements\n- ASHRAE 2011 common 
 environmental guidelines\n- ETSI EN 300 019 Class 3.1\n- Select and de
 ploy of new IT equipment\n- Data centre utilisation, management and pl
 anning (software, IT and M&E)\n- Physical building layout (site select
 ion, water sources, use of economizers, etc.)\n- Lighting control (EU 
 standards, LEED, BREEAM, etc.)\n- Monitoring (energy use & environment
 al reporting, etc.)\n- Items under consideration (rotary UPS, mechanic
 al UPS, etc.)\n- Minimum practices for data center energy efficiency\n
 - Metrics used to measure data center energy efficiency\n\nFor more in
 formation, please visit the seminar website at http://www.stmedia-asia
 .com/trainings.html OR http://www.stmedia-asia.com/newsletter_4.html\n
  \n\nFor more information visit http://www.datacenterprofessionals.ne
 t/events/2-day-training-seminar-on-eu-code-of-conduct-for-data-center
DTSTART;TZID=Europe/Amsterdam:20120817T000000
DTEND;TZID=Europe/Amsterdam:20120818T235900
CATEGORIES:training, seminar
LOCATION:10th Floor, Central Building,
WEBSITE:http://www.stmedia-asia.com/newsletter_4.html
URL:http://www.stmedia-asia.com/newsletter_4.html
CONTACT:(852) 3796 3026
ORGANIZER:Strategic Media Asia Limited
ATTACH;FMTTYPE="image/jpeg":
ATTENDEE;ROLE=REQ-PARTICIPANT;PARTSTAT=ACCEPTED;RSVP=TRUE;CN="Strategi
 c Media Asia":http://www.datacenterprofessionals.net/profile/stmedia
ATTENDEE;ROLE=REQ-PARTICIPANT;PARTSTAT=ACCEPTED;RSVP=TRUE;CN="Gus Sass
 ine":http://www.datacenterprofessionals.net/profile/GusSassine
END:VEVENT
END:VCALENDAR