BEGIN:VCALENDAR
PRODID:NingEventWidget-v1
VERSION:2.0
METHOD:PUBLISH
BEGIN:VTIMEZONE
TZID:Europe/Amsterdam
X-LIC-LOCATION:Europe/Amsterdam
BEGIN:DAYLIGHT
TZOFFSETFROM:+0100
TZOFFSETTO:+0200
TZNAME:CEST
DTSTART:19700329T020000
RRULE:FREQ=YEARLY;BYMONTH=3;BYDAY=-1SU
END:DAYLIGHT
BEGIN:STANDARD
TZOFFSETFROM:+0200
TZOFFSETTO:+0100
TZNAME:CET
DTSTART:19701025T030000
RRULE:FREQ=YEARLY;BYMONTH=10;BYDAY=-1SU
END:STANDARD
END:VTIMEZONE
BEGIN:VEVENT
UID:2336802:Event:41829
DTSTAMP:20260507T231146Z
SUMMARY:Is Perimeter Cooling Dead? Going Green in the Data Center
DESCRIPTION:\"IS PERIMETER COOLING DEAD?”\n\n\n“BREAKFAST AND LEAR
 N” INFORMATION:\nDATE: WEDNESDAY, AUGUST 19TH\nTIME: 8:00-11:00\nLOC
 ATION: APC DEMO DATA CENTER\n6380 W 54TH AVENUE\nARVADA, CO 80002\n\n\
 n\n\nPRESENTATION OVERVIEW:\n\n\nTraditional data center \"room\" cool
 ing is unable to accommodate the latest generation of high and variabl
 e density IT equipment resulting in cooling systems that are inefficie
 nt, unpredictable, and low in power density. To address these problems
  row-oriented and rack-oriented cooling architectures have been develo
 ped. This presentation will examine and contrast the 3 basic cooling a
 pproaches: room, row, and rack architectures. Each approach has an app
 ropriate application but row-orientated cooling is emerging as the sol
 ution of choice for most next generation data centers. Next generation
  data centers demand the flexibility, predicability, scalability, redu
 ced electrical power consumption, reduced TCO, and optimum availabilit
 y that row and rack-oriented cooling architectures can provide. Additi
 onally, the factors that gave rise to the establishment and use of the
  raised floor in the data center environment are presented. For many a
 pplications the use of the raised floor is no longer justified or desi
 rable. To learn more on this topic, join us for breakfast and an educa
 tional presentation that examines “is perimeter cooling dead”?\n\n
 \nPRESENTATION TOPIC HIGHLIGHTS:\n\n\n-Discuss the following cooling a
 pproaches: room, row and rack-based cooling architectures.\n-Compariso
 n of cooling architectures: challenges in agility, availability, lifec
 ycle costs, serviceability, and manageability\n-Special issues: capaci
 ty utilization, humidification, electrical efficiency, water near IT e
 quipment, location and redundancy.\n-Elements of the raised floor and 
 problems associated with using a raised floor.\n-Hurdles to eliminatin
 g the raised floor\n-Designing without a raised floor.\n\n\nAttendees 
 are invited to stay after the educational presentation to walk through
  a demonstration data center and experience InfraStruXure architecture
  from APC by Schneider Electric. All attendees are eligible for a free
  Critical Facility Energy Profile conducted at their own facility. For
  additional details on the CFEP offer and to RSVP for this event pleas
 e contact Ryan Mordhorst at r.mordhorst@apcdistributors.com or 720-975
 -4253.\n\n\nABOUT THE GUEST SPEAKER:\n\n\nDon Melchert has been workin
 g with critical facilities since 1992. He has lead the efficient build
  out of new data centers such as Sisters of Mercy hospitals and has ma
 naged critical facilities to include ConAgra Foods, Coca-Cola Enterpri
 ses and the Department of Education. For Schneider Electric, Don is no
 w the primary instructor for Data Center University, bringing with him
  the knowledge and experience gained from assisting customers througho
 ut North America become more self sufficient and energy conscious.\n\n
 \nABOUT THE SPONSORS:\n\n\nUniversal Networking Services, LLC (UNS, LL
 C) specializes in mission-critical power and cooling solutions for wir
 ing closets, server rooms and data centers. UNS, LLC provides product 
 acquisition, design/engineering, installation management and maintenan
 ce services. APC is considered a global leader in data center physical
  infrastructure (DCPI) solution, APC sets the standard in its industry
  for quality, innovation and support.\n\nFor more information visit ht
 tp://www.datacenterprofessionals.net/events/is-perimeter-cooling-dead
DTSTART;TZID=Europe/Amsterdam:20100819T080000
DTEND;TZID=Europe/Amsterdam:20100819T110000
CATEGORIES:educational
LOCATION:APC Demo Data Center
WEBSITE:
URL:
CONTACT:720-975-4253
ORGANIZER:Ryan Mordhorst Please RSVP
ATTACH;FMTTYPE="image/jpeg":
ATTENDEE;ROLE=REQ-PARTICIPANT;PARTSTAT=ACCEPTED;RSVP=TRUE;CN="Ryan Mor
 dhorst":http://www.datacenterprofessionals.net/profile/RyanMordhorst
END:VEVENT
END:VCALENDAR
