BEGIN:VCALENDAR
PRODID:NingEventWidget-v1
VERSION:2.0
METHOD:PUBLISH
BEGIN:VTIMEZONE
TZID:Europe/Amsterdam
X-LIC-LOCATION:Europe/Amsterdam
BEGIN:DAYLIGHT
TZOFFSETFROM:+0100
TZOFFSETTO:+0200
TZNAME:CEST
DTSTART:19700329T020000
RRULE:FREQ=YEARLY;BYMONTH=3;BYDAY=-1SU
END:DAYLIGHT
BEGIN:STANDARD
TZOFFSETFROM:+0200
TZOFFSETTO:+0100
TZNAME:CET
DTSTART:19701025T030000
RRULE:FREQ=YEARLY;BYMONTH=10;BYDAY=-1SU
END:STANDARD
END:VTIMEZONE
BEGIN:VEVENT
UID:2336802:Event:118548
DTSTAMP:20260507T222108Z
SUMMARY:Technical Training Seminar in HVAC Design and Cooling Speciali
 st for Data Center
DESCRIPTION:The American Society of Heating, Refrigeration and Air-Con
 ditioning Engineers (ASHRAE) Technical Committee (TC) 9.9 has publishe
 d 10 guidelines covering a wide range of data center design and operat
 ional issues. These ASHRAE works are also referenced in the TIA-942 da
 ta center standard.\n \nWe provide an introduction of critical infras
 tructure system (E&M) that supports typical data centers and prepare i
 ndividual to fully understand the main components that facilitate data
  centre design & build by exploring the standards of TIA-942 and Up-ti
 me Tier levels.\n\nFurthermore, we introduce key challenges and consid
 er different criteria, from design, testing, commissioning, sustainabi
 lity and efficiency, of HVAC (Heating, Ventilation, and Air Conditioni
 ng) system in a data center. All sections are designed for data center
  operators, engineers and E&M professionals to enrich their relevant k
 nowledge in data center facilities and HVAC design.\n \n \n1) Dataco
 m Equipment Power Trends and Cooling Applications\n- load trends and t
 heir application\n- air cooling of computer equipment\n- liquid coolin
 g of computer equipment\n \n2) Design Consideration\n- design criteri
 a\n- HVAC load\n- computer room cooling\n- air distribution\n- liquid 
 cooling\n- availability and redundancy\n- integration with other MEP s
 ystem\n- controls - computer fluid dynamics\n \n \n3) Testing and Co
 mmissioning\n- air cleanliness test\n- heat load test\n- factory accep
 tance test\n- site acceptance test\n- integrated performance test (IST
 )\n \n4) Sustainable Design\n- combined heat power plant (CHP)\n- sol
 ar cooling\n- geothermal cooling\n- evaporative cooling\n- air side ec
 onomizers\n- desiccant unit\n \n5) Energy Efficiency\n- power usage e
 ffectiveness\n- chilled water plant optimization\n- water side and air
  side equipment\n- part load operation\n- controls and energy manageme
 nt\n- LEED certified data center\n- building energy code\n\nFor more i
 nformation visit http://www.datacenterprofessionals.net/events/technic
 al-training-seminar-in-hvac-design-and-cooling-specialist
DTSTART;TZID=Europe/Amsterdam:20130424T000000
DTEND;TZID=Europe/Amsterdam:20130425T235900
CATEGORIES:training, seminar
LOCATION:Hong Kong
WEBSITE:http://www.stmedia-asia.com/trainings.html
URL:http://www.stmedia-asia.com/trainings.html
CONTACT:(852) 2117 3893
ORGANIZER;CN="Strategic Media Asia":http://www.datacenterprofessionals
 .net/profile/stmedia
ATTACH;FMTTYPE="image/jpeg":
ATTENDEE;ROLE=REQ-PARTICIPANT;PARTSTAT=ACCEPTED;RSVP=TRUE;CN="Strategi
 c Media Asia":http://www.datacenterprofessionals.net/profile/stmedia
END:VEVENT
END:VCALENDAR
